Features phase angle limit is adjustable over the range of 1 to 99 degrees.
Sync check relay function.
Connecting two electrical systems that are not closely matched can cause expensive damage and disturbance to the electrical.
Today these are digital microprocess.
The synchro check relay spau 140 c can be used for both synchro check functions and voltage check functions.
Then sync check verifies that this angle is less than the front panel phase angle selector setting.
For this reason it is normal practice to have the sync check relay function provided in a different package than the automatic synchronizing relay to.
In the design of electrical power systems the ansi standard device numbers ansi ieee standard c37 2 standard for electrical power system device function numbers acronyms and contact designations identifies the features of a protective device such as a relay or circuit breaker these types of devices protect electrical systems and components from damage when an unwanted event occurs such.
The synchro check function is used when two separate networks or two electrically interconnected network sections are to be connected together.
The synchro check relay can be used to assist in the semi automatic parallelling of two ac power systems.
The voltage check function is used when a dis connected bus line is to be connected to an.
The vr 300 is a fixed mounted industrial grade protective relay that offers multiple protective features in a single package.
Sync check relay the be1 25 sync check relay monitors the voltages on both sides of a circuit breaker and determines that proper phase angle and voltage exist prior to closing the circuit breaker.
Sync check relay synchronism check relay are relays that allow unattended synchronization of a machine with a system.
It provides voltage protection functions including over undervoltage loss of phase over underfrequency monitoring and sync check.
The synchro check function is used when two separate networks or two electrically interconnected network sections are to be connected together.
The relay will drop out or stay in according to the function set ting on the sypd as described above.
The volt free relay contacts change state when the voltage level phase relationship and frequency are within the selected synchronising limits.
The voltage check function is used when a disconnected bus line is to be connected to an.
The synchro check relay spau 140 c can be used for both synchro check functions and voltage check functions.
If the measured angle has met this criteria for the time period defined by the front panel time delay setting the sync output contact closes.